Digital Force & Torque Gauges

    Specifications - Torque Gauges and Indicators

                                            TT01                                     TT05                                   TT02                        TT03
                                                                                                                                                       ±0.5%
    Accuracy (% of full scale)              ±0.3%                                    ±0.3%                                ±0.3%
    Password protection                                                                                                                                   No
    Sampling rate                                                                    Yes                                                               2,000 Hz
    Resolution
    Outputs                                            7,000 Hz                                                                                          USB

       USB / RS-232                                                                                              1/1,000                                 N/A
       Mitutoyo (Digimatic)                                                                                                                              N/A
       Analog                                          USB, RS-232 Mitutoyo, Analog                                                                      N/A
       General purpose I/O                                                                                                                                No
       Set point                                                                           Configurable up to 115,200 baud
    MESURTM Lite software included
    Communication with MESURTMgauge                    Serial BCD suitable for all Mitutoyo SPC-compatible devices
    and MESURTM Lite software
    Data memory                                        ±1 VDC, ±0.25% FS. + for compression / CW, - for tension / CCW
    Data memory deletion
    Statistics calculations                            Three open drain outputs, one input
    Analog load bar graph shown on display
    Keypad password protection                                   Yes, three open drain lines
    Peak readings calculated
    Break detection*                                                                                             Yes
    1st / 2nd peak detection*
    Programmable audible tones                         Single point or continuous data, send from gauge or request from software
    No. of units of measurement
    Battery life (with backlight on/off)                         1,000 readings, with output                                                           No
    Safe overload
    Weight (lb [kg])                                   Individual data points, or clear all                                                            N/A

    Included items                                     Max, min, mean, std. dev., number of readings, with output                                      N/A

                                                                                                                 Yes

                                                                 Yes, for calibration and keys                                                         No

                                                                                                                 Yes

                                                                                     Yes No

                                                                                     Yes No

                                                                                                                 Yes

                                                                                     53

                                                       Backlight on: up to 7 hours of continuous use, Backlight off: up to 24 hours of continuous use

                                                                 150% of full scale (display shows “OVER” at 110% and above)

                                            8.4 [3.8]            10.9 [4.9]                                               5.8 [2.6]                    1.8 [0.8]

                                            1/4” hex to 3/8” square adapter (TT02 Only), Carrying Case (TT03 only) Universal voltage AC adapter, battery, quick-start guide,
                                            resource CD (USB driver, MESURTM Lite software, MESURTMgauge DEMO software, and user’s guide), and certificate of calibration.

    * With configurable automatic data output, data storage, and zero function upon detection of peak value(s).

14