          Feature        Part No.  Description                                                                                Requirements
FollowMeTM              AF008
                        AF009      Crosshead movement responds to manually pushing or pulling on the force gauge              - Series 7 or 5 gauge or indicator
Travel indication                  shaft or load cell. Increasing force produces greater speeds. Ideal for setups and quick   - 09-1214 interface cable
                        AF010      positioning.
Computer control        AF011                                                                                                 - Field hardware installation required.
Programmable travel     AF012      Travel is indicated on the control unit display, with output via USB. An internal scale    - If data output to a PC is required, add 09-1214 and 09-1158
limits                             utilizing Renishaw technology produces significantly higher accuracy than with
Overload                AF013      conventional rotary encoder-based designs. Backlash and nonlinearity are virtually          cables, and a Series 7 or 5 gauge or indicator.
protection                         eliminated. The most recent position is memorized between power cycles.
                        AF014                                                                                                 - Series 7 or 5 gauge or indicator
Auto return             AF016      The ESM303 may be fully controlled by a PC through a custom-written program in any         - AF009 travel indication
                        AF017      language supporting ASCII communications. Also responds to the legacy Chatillon            - AF011 programmable travel set points
Cycling / dwell time    AF018      TCD command set and legacy Nexygen TCD software (not available from Mark-10).              - 09-1214 interface cable
Independent up and      AF019                                                                                                 - 09-1158 USB output cable
down speeds             AF020
Low speed range                    The stand stops at or cycles between programmable upper and lower travel distances. - AF009 travel indication option
extension               AF021
High speed range        AF022      Protects a force gauge or force sensor against overload. Program the desired percent-      - Series 7 or 5 gauge or indicator
extension               AFCOMP     age of full scale of the gauge. Adjustable analog output voltage setting allows the        - 09-1214 interface cable
Break detection                    stand to interface with virtually any gauge with analog output.
Load holding                                                                                                                  - If reversing at force set point: Series 7 or 5 gauge or indica-
                                   The crosshead moves to a limit switch, force set point, travel position, or break, then     tor and 09-1214 interface cable
Preload / sample                   stops and reverses direction at full speed to the opposite limit.
touch                                                                                                                         - If reversing at travel limit: AF011 programmable travel limits
Profiles                           Same as auto return, but with the ability to program up to 100,000 cycles. Program-         option
Complete options                   mable dwell time for upper and lower limits (set independently) can be set up for up
package                            to 10,000 seconds.                                                                         - If reversing at break: AF019 break detection option and
                                                                                                                               09-1214 interface cable

                                                                                                                              - Same as auto return, at the same speed in each direction.
                                                                                                                               Add AF016 for independent up and down speeds.

                                   Individually configure speeds for the up and down directions.                              ---

                                   Extends the standard speed range down to                                                   ---
                                   0.02 in/min (0.5 mm/min).

                                   Extends the standard speed range up to                                                     ---
                                   45 in/min (1,100 mm/min).

                                   Crosshead stops at a sudden drop in force.                                                 - Series 7 or 5 gauge or indicator
                                   Programmable percentage of peak force.                                                     - 09-1214 interface cable

                                   Dynamically adjusts the crosshead position to maintain a programmed load for an            - Series 7 or 5 gauge or indicator
                                   indefinite or specified period of time.                                                    - If a specified time is required, add AF014 cycling / dwell

                                                                                                                               time option
                                                                                                                              - 09-1214 interface cable

                                   Stops the crosshead and/or zeroes the travel display at an initial preload - useful in     - AF009 travel indication
                                   tensile, compression, spring, elongation, and other applications. Preload is program-      - Series 7 or 5 gauge or indicator
                                   mable as a percentage of force gauge/load cell full scale. Three modes: (1) stop, (2)      - 09-1214 interface cable
                                   stop and zero, and (3) zero without stopping.

                                   Save and recall sets of test parameters, such as speeds, travel limits, preloads, etc. Up  ---
                                   to 50 profiles may be stored.

                                   Includes all funtions listed above, plus 09-1214 interface cable and 09-1158 USB cable.
                                                                Requires a Series 7 or 5 gauge or indicator.

Ordering Information*

ESM303                  Motorized test stand,110V**                                               * Controller options part numbers indicated in the table above.
09-1214                 Interface cable, gauge / indicator to ESM303                              ** E SM303 contains a universal power supply (80 - 240V) and
09-1158                 USB output cable
AC1062                  Load cell / indicator mounting kit                                           includes a power cord with US plug. Add suffix ‘E’ for Euro plug, ‘U’
ESM303-001-1 / -2 / -3  Single column extension, 6 / 12 / 24 in. [150 / 300 / 600 mm]                for UK plug, or ‘A’ for Australian plug. Ex: ESM303E
ESM303-002-1 / -2 / -3  Double column extension, 6 / 12 / 24 in. [150 / 300 / 600 mm]