Model BGI |
Series MGT |
Series CT |
Series ST |
|
Accuracy |
±0.1% of full scale ± 1 digit + sensor |
±0.5% of full scale ± 1 digit |
|
Sampling rate |
65 readings/s |
30 readings/s |
65 readings/s |
|
Display rate (updates/s) |
2.5 / 65 in peak mode |
2.5 / 30 in peak mode |
2.5 / 65 in peak mode |
|
Power |
AC or rechargeable battery.
Includes Intelligent
Power Management System (IPM). IPM warns the user via a "LO BAT" indicator
and then powers off the gauge. |
AC
or non-rechargeable battery, includes IPM. |
|
Battery life |
8-10 hours of continuous use |
30
hours of continuous use |
|
Peak capture |
Yes, CW and CCW |
|
Units of measurement |
ozFin / lbFin, kgFmm / kgFm, Ncm / Nm |
lbFin, kgFmm, Ncm |
|
Outputs |
Standard |
N/A |
Optional |
Standard |
|
RS-232 |
Fully configurable up to 9600 baud. Includes
Gauge Control Language (GCL). |
N/A |
Fully configurable up to 9600 baud. |
|
Mitutoyo (Digimatic) |
Serial BCD suitable for all Mitutoyo SPC-compatible
devices |
N/A |
Serial BCD suitable for all Mitutoyo SPC-compatible
devices |
|
Analog |
±1 VCD, ±0.25% of full scale at capacity.
Positive for compression, negative for tension. |
N/A |
|
General purpose I/O |
Three open collector outputs and one input
(utilizing Mitutoyo lines) |
N/A |
|
Set points |
Three open collector lines (utilizing Mitutoyo
lines) |
N/A |
|
Analog |
±1 VCD, ±0.25% of full scale at capacity.
Positive for compression, negative for tension. |
N/A |
|
Configurable Settings |
Analog filters, digital filters, outputs selection, automatic output
(RS-232), automatic shutoff, initial (default), averaging mode, calibration |
N/A |
RS-232 and Mitutoyo output settings |
|
Safe overload |
Dependent upon sensor (display
shows "----" at 110% and above) |
150% of full scale (display
shows "----" at 110% and above) |
|
Weight |
0.9 lb (0.4 kg) + sensor |
1.8 lb (0.8 kg) |
10 lb (4.5 kg) |
4.8 lb (2.2 kg) |
|
Included accessories |
Carrying case, AC adapter/charger,
rechargeable 7.2V battery, NIST-traceable certificate of calibration |
Carrying case, AC adapter, non-rechargeable
7.2V battery, NIST-traceable certificate of calibration, chuck key |
Set of four posts, AC adapter,
non-rechargeable 7.2V battery, NIST-traceable certificate of calibration |
AC adapter, non-rechargeable 7.2V battery, NIST-traceable certificate of calibration |
|
Environmental requirements |
40°F - 100°F [5°C - 45°C], <96% humidity
(non-condensating) |
|
Housing construction |
Aluminum |